Midmark M11 Steam Sterilizer Refurbished

Midmark M11 Steam Sterilizer Refurbished Autoclave 011 Version
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: Y-Midmark-M11-011
Call for pricing

Midmark M11 Steam Sterilizer Refurbished Autoclave

SPECIFICATIONS
Physical Dimensions:
Overall Length................................. 48.3 cm (19 in)
Overall Width................................... 38.1 cm (15 in)
Overall Height ................................. 40.6 cm (16 in)
Counter Area................................... 41.9 cm x 35.6 cm (16.5 x 14 in)
Chamber ......................................... 22.9 cm Diameter x 38.1 cm depth
(9 in Diameter x 15 in depth)
Large Trays (2)................................ 30.5 cm x 20.3 cm x 2.5 cm
(12 in x 8 in x 1 in)
Small Trays (2) ................................ 30.5 cm x 14.0 cm x 2.5 cm
(12 in x 5.5 in x 1 in)
Weight:
Empty Reservoir.............................. 32 Kgs (70 lbs)
With Shipping Carton ...................... 35 kgs (78 lbs)
Water Reservoir Capacity............. Approximately 3.3 Liters to Full Mark
(0.88 gallons)
Electrical Requirements:
NOTE: A separate (dedicated) circuit is recommended for this sterilizer. The
sterilizer should not be connected into an electrical circuit with other appliances
or equipment unless the circuit is rated for the additional load.
100 VAC, 50/60 Hz Model ............... 20 AMP Circuit, Single Phase
120 VAC, 60 Hz Model.................... 15 AMP Circuit, Single Phase
220-240 VAC, 50/60 Hz Model........ 10 AMP Circuit, Single Phase
Maximum Power Consumption:
100 VAC, 50/60 Hz Model ............... 1425 Watts, 14.2 A @ 100V
120 VAC, 60 Hz Model.................... 1425 Watts, 11.9 A @ 120 V
220-240 VAC, 50/60 Hz Model........ 1500 Watts, 6.3 A @ 240 V
Chamber Pressure at
132°C (270°F) .................................215 kPa (31 psi)
Safety Valve Setting ......................276 kPa (40 psi)
Certifications .................................ISO-9001 Certified

Products specifications
Sterilizer Type Automatic Sterilizer
Sterilizer Door Size 11 inches
Sterilizer Chamber Depth 18 inches
Sterilizer Dimension 24" x 18" x 18" (605mm x 452mm x 452mm)
Sterilizer Power Voltage 120V Single Phase
Sterilzier Power Current 15A
Loading Methods Front Load
Sterilizer Program Unwrapped, Pouches, Packs, Handpieces (Midmark)
Sterilizer High Temperature 275F (134C)
Printer Option
Color Beige
Type of Heating Element Internal Heating Element
Sterilizer Speed Standard
Type of Door Hinge Door
Laboratory Customer Yes
Industry Customer Yes
Government Customer Yes
Tattoo, Beauty Salon Customer Yes
Medical Doctor Yes
Dentist Customer Yes
FDA Certificate Yes
ASME Certificate Yes
UL Cerificate Yes
Warranty Parts and Labor 90 days